►Strong transient voltage resistance to protect terminal module
►Dual diaphragm overload structure can easily cope with high overload tests
►Accurate filling fluid technology eliminates effects of temperature and static pressure
►High strength metal electrical protection housing meets the most rigorous environmental application
✔ Responsive after-sales service / Customizable / High quality / One-year warranty
|
2 kPa ... 40 MPa |
||
Output signal |
4-20mA, 4-20mA/HART |
||
Accuracy |
±0.1% URL (standard), ±0.075% URL |
||
Stability |
±0.2% URL/ 5 years
|
||
|
SUS 316L, Hastelloy |
||
Medium temperature |
-20℃ ... 85℃, integrated LCD display -20℃ ... 70℃ |
||
IP rating |
IP 67
|
||
Process connection |
M20 x 1.5 (M), G1/2(M), G1/4(M)
1/2", 1/4" NPT(M)
1/2", 1/4" NPT (F)
|
||
Approvals |
CSA, ATEX, IECEx, NEPSI, RoHS, CE
|
|
|